3. Web Server Quick Guide
3.1. Introduction
These instructions describe the TLX CN Pro Web Server, which facilitates remote access to the
inverter.
The Web Server is available in TLX CN Pro and TLX CN Pro+ inverters only.
Refer to the download area at www.danfoss.com/solar for the newest instructions.
3.2. Supported Characters
For all language versions, the Web Server software supports characters compatible with Uni-
code.
For plant, group and inverter name, only the following characters are supported:
Letters abcdefghijklmnopqrstuvwxyz
Capital letters ABCDEFGHIJKLMNOPQRSTUVWXYZ
Numbers 0123456789
Special characters - _.
Note! No spaces are allowed in inverter name.
3.3. Access and Initial Setup
3.3.1. Access via PC Ethernet Interface
Change the Web Server logon and password of the master inverter immediately
for optimal security when connecting to the internet. To change the password go
to [Setup Web Server Admin].
Setup Sequence:
1. Select which inverter will be set up as master.
2. Open the cover of this inverter. Refer to the TripleLynx CN Installation Manual for in-
structions.
3. Connect the inverter RJ45 interface to the PC Ethernet interface using a patch cable
(network cable cat5e, crossed or straight through).
4. For Windows 7 configure the inverter via the setup wizard in the display, see the chap-
ter
User Interface
. Do not follow the remaining steps.
5. On the PC, wait until Windows reports limited connectivity (if no DHCP is present).
Open the internet browser and ensure pop-ups are enabled.
6. Type http://invertername in the address field:
Find the serial number on the product label, located on the side of the hous-
ing.
'Invertername' is the final 10 digits of the serial number (1).