Programming
■ Special Functions
■ Introduction
The purpose of the special functions is to select and adjust special functions for over voltage control, brake
resistor and power, brake check, speed controlling parameters, LC filter, mains failure functions and flying
start.
PNU Parameter Factory setting Range Changes 4-Setup Conversion Data
# description during operation index type
400 B
Brake function/overvoltage control
Off Yes No 0 5
401 B
Depends on the unit Yes No -1 6
402 B
Depends on the unit Yes No 2 6
403 P
Warning Yes No 0 5
404 B
Off Yes No 0 5
405 R
Manual reset Yes Yes 0 5
406 A
5 sec. 0 - 10 sec. Yes Yes 0 5
409 T
5 sec. 0 - 60 sec.
417 S
Speed PID proportional gain
0.015 0.000 - 5.000 Yes Yes -3 6
418 S
Speed PID integration time
200 ms 2.00 - 20.000
ms
Yes Yes -4 7
421 S
Speed PID low-pass filter
5/20 1-500 ms Yes Yes -4 6
445 F
Disable Yes Yes 0 5
458 L
No 0-1 No Yes 0 5
459 C
2 μF 0.1-100 μF No Yes -1 6
460 I
7 mH 0.1-100 mH No Yes -1 6
462 S
Off 0-100% Yes Yes 0 6
463 A
0.91 = OFF 0.50-0.91 Yes Yes -2 S16
470 A
100% 20%-500% Yes Yes 0 U16
471 A
50 RPM 0-1500 RPM Yes Yes 67 U16
472 A
50 RPM 0-1500 RPM Yes Yes 67 U16
✭ = factory setting. () = display text [] = value for use in communication via serial communication port