Do not place the thermostat in a way that
it will be exposed to direct sunlight.
Note: A floor sensor enables a more accu-
rate temperature control and is recom-
mended in all floor heating applications
and mandatory under wooden floors to
reduce the risk of over-heating the floor.
Place the floor sensor in a conduit in an appropriate
place where it is not exposed to sunlight or draft
from door openings.
Equally distant and >2cm from two heating cables.
The conduit should be flush with the floor surface -
countersink the conduit if necessary.
Route the conduit to the connection box.
The bending radius of the conduit must be min
50mm.