FP715Si
Electronic 2-Channel Full Programmer for
Heating and Hot Water with Service Interval Timer
Installation Guide
Danfoss Heating
MAKING MODERN LIVING POSSIBLE
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - Installation Guide

FP715SiElectronic 2-Channel Full Programmer for Heating and Hot Water with Service Interval TimerInstallation GuideDanfoss HeatingMAKING MODERN LIVING

Strona 2 - Certification Mark

FP715SI10GB(Applies only to 230 volt models)Wiring conversions can be used when replacing the following programmers with the FP715 Si. Some time contr

Strona 3

Danfoss Heating11GBW HTG ONWires other than links in these terms go to LIVENOTEThis conversion applies only if...An additional terminal block may be

Strona 4 - 3.0 Installation

FP715SI12GBTable A continuedDANFOSS RANDALL FP715, CP715 (PUMPED)MAINSDHW OFFHTG OFFDHWONNL1 2 3SANGAMO S409/3 3,6 7 4 2 5SATCHWELL LIBRA & DHP 22

Strona 5 - A & B on wallplate

Danfoss Heating13GBW HTG ONWires other than links in these terms go to LIVENOTEThis conversion applies only if...An additional terminal block may be

Strona 6 - 3.2 DIL Switch Settings

FP715SI14GBTable BDANFOSS RANDALL FP715, CP715 (PUMPED)MAINSDHW OFFHTG OFFDHWONNL1 2 3DANFOSS RANDALL 922/972 N L 1 4 3DANFOSS RANDALL 102/102E/102E7

Strona 7 - 5.0 Copy Functions Explained

Danfoss Heating15GBW HTG ONWires other than links in these terms to LIVENOTEThis conversion applies only if...An additional terminal block may be req

Strona 8

FP715SI16GBTable B cont...DANFOSS RANDALL FP715, CP715 (PUMPED)MAINSDHW OFFHTG OFFDHWONNL12 3SMITHS IND. CENTROLLER 1000 N L - - 3SMITHS IND. CENTROLL

Strona 9 - 6.0 Service Interval Timer

Danfoss Heating17GBW NHTG ONWires other than links in these terms to LIVENOTEThis conversion applies only if...An additional terminal block may be r

Strona 11 - Danfoss Heating

Danfoss Heating19GB

Strona 12 - (PUMPED)

FP715SI2GBFor a large print version of these instructions please call Marketing on 0845 121 7400.Danfoss can accept no responsibility for possible err

Strona 13

Part No. 38161v01s7-06 01/11Danfoss Ltd.Ampthill RoadBedford MK42 9ERTel: 01234 364621Fax: 01234 219705Email: [email protected]: www.heati

Strona 14

Danfoss Heating3GBFP715SiElectronic 2-Channel Full Programmer for Heating & Hot Water with Service Interval TimerIndex1.0 Installation Overview ..

Strona 15

FP715SI4GBSpecifi cation 230V model 24V modelPower supply230 Vac, ±15%, 50/60 Hz24 Vac, ±15%, 50/60 HzSwitching action2 x SPDT internally linked, Type

Strona 16 - Table B cont

Danfoss Heating5GBNL1234230VFused 3AOFFDHWOFFHTGONDHWONHTGELECTRONICSN/ON/CN/ON/C• The wallplate must be securely mounted either directly to the wall

Strona 17

FP715SI6GBNot UsedGravity5/2 Day7 DaySw.1Sw.2Sw.3Sw.4Not UsedPumped7 Day or 24 Hour24 HourBefore mounting the unit, ensure the 4 DIL switches on the r

Strona 18

Danfoss Heating7GBOption 8 - (Advanced Copy Functions)Press NEXT, then + or - to change between the following copy options:(0) Standard copy in 7 day

Strona 19

FP715SI8GBAB Copy: The AB copy function is available in 5+2 mode only and only if activated in the Advanced Programming setting.A and B days, when se

Strona 20 - Danfoss Ltd

Danfoss Heating9GBThe FP715 Si is fi tted with an installer setback service interval timer. If this feature is required please contact our technical de