SET2EInstallation & User Instructionselectronic 24-hour mini-programmer for heating & hot water

Strona 2

10What is a programmer?... an explanation for householders.Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central he

Strona 3 - Installation Instructions

11User InstructionsYour programmerThe SET2E allows you to switch your hot water & heating on and off automatically, at times that suit you. The pr

Strona 4 - Installation

12Programming the unitYou can programme your heating to come on and go off twice a day, to suit your requirements. To programme your unit: Setting th

Strona 5

13Remember to return the slider switch to the RUN position after programming!Programming the unit  Move the slider to the 1st ON position and use

Strona 6 - Typical fully pumped system

14Advance  Press the ADVANCE button once to move forward to the next programmed event If the system is on it will go off. If it is off it will com

Strona 7 - Replacement

15 TIMED - the heating will come on and go off at the times you have programmed (including any temporary overrides you may select) CONSTANT - the

Strona 8 - DANFOSS RANDALL

Danfoss Randall LtdAmpthill RoadBedfordMK42 9ERTel: 01234 364621Fax: 01234 219705Still having problems?Call your local heating engineer:Name:Tel:Visit

Strona 9

2INDEXIndexInstallation Product specifi cation 3 Installation 4-5 Wiring 5-7 Replacement 7-9 User What is a Programmer? 10 Your programmer 11

Strona 10 - What is a programmer?

3Please Note: This product should only be installed by a qualifi ed electrician or competent heating installer, and should be in accordance with the cu

Strona 11 - User Instructions

4Installation1. Fix the wallplate to the wall or fl ush mounted box as required. The connections are at the top and the vertical centre line of

Strona 12 - Preset programme

57. Locate the module on the latches at the bottom of the wallplate and hinge upwards to fully engage the unit connectors into the wallplate. T

Strona 13 - Temporary User Overrides

6Typical Gravity DHW with pumped central heatingDHW = Domestic Hot WaterWiring Typical fully pumped system with spring return zone valve in heatingGiv

Strona 14 - Manual Switch Settings

7Typical fully pumped system with 3-port mid-position valveWiring Replacement Please see overleaf for a table containing replacement wiring informatio

Strona 15 - Memory Backup

8DANFOSS RANDALLSET2Ewith terminals L - 2 and 1 - 5 linkedMAINS WATER HEATINGNOTE This conversion applies only if..An additional terminal block is req

Strona 16 - Still having problems?

9POTTERTON EP2000NL 3 -1 4 52Programme selectors linkedABCDSANGAMO M5 410 FORM 44,5 3 1,6 - 2 8 - 7Terminals 1 & 6 are linkedSANGAMO S409 FORMS 1