Danfoss TP5000 si range Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Termostaty Danfoss TP5000 si range. Danfoss TP5000 si range Programming instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - TP5000 Si Range

TP5000 Si RangeInstallation and User Instructions Electronic 5/2 day programmable room thermostatMains, Battery and RF versionsGB ®Certification Mar

Strona 2

10Installation InstructionsGBOption 32 - Enable O at lower limitThis enables an OFF function to be selected if a set point below the lower limit is

Strona 3

11Installation InstructionsGBOption 36 - Set temperature override ruleThis establishes the degree of temperature override available to the user. Press

Strona 4 - Installation

12Installation InstructionsGBOption 70 - Keyboard disable rulesThis establishes the degree of functionality of the keyboard available to the user. It

Strona 5 - Battery Installation

13Installation InstructionsGBOption 74 - Date format for calendar clockThis allows date format to be chosen. Press + until Option 74 is displayed, use

Strona 6

14Installation InstructionsGBOption 94 - Con gure digital input switch type, “A” models only, (option 90 set to 3)This allows switch type of digital

Strona 7 - IMPORTANT

15What is a programmable room thermostat?... an explanation for householdersA programmable room thermostat is both a programmer and a room thermostat.

Strona 8 - Installer advanced

16An introduction to your programmable room thermostatYour programmable room thermostat allows you to programme di erent temperatures at di erent ti

Strona 9

17Note: If set up for 4 events per day, events 3 & 4 are skipped. If set up for 2 events per day, events 2, 3, 4 & 5 are skipped. In both case

Strona 10 - Installation Instructions

18Setting the datePress and hold Λ and PROG for 3 seconds, to display date in dd/mm/yy format. The YEAR number will  ash, use Λ or V to correct the y

Strona 11

19Accepting the preset programmesIf you are happy with the preset times shown in the table on page 17you need take no further action.Changing the pres

Strona 12

2IndexInstallation Instructions 3-14Product Speci cation 3Installation 4Cable Access and Wiring 5-8Installer Advanced Programming Options 8-14Use

Strona 13

20User InstructionsGBb) Use the + and - buttons to adjust the TIME (press and hold to change in 10 minute increments).c) Use the Λ and V buttons to ad

Strona 14

21Changing preset programmes for AB programming(Installer setting must be in 5/2 day mode)Press and hold PROG and V for 3 seconds. The display will ch

Strona 15 - User Instructions

22User InstructionsGBProgramming “B” programme days and eventsa) Press PROG until the  rst preset time and temperature (Event 1 for Programme B) appe

Strona 16

23User InstructionsGBThis override will automatically be cancelled at the beginning of the next programmed event. Please note that your installer may

Strona 17 - Customising the display

24User InstructionsGBChanging the clock forwards and backwardsThis is handled automatically, however, if the manual changeover has been selected (User

Strona 18 - Setting the correct day

25User InstructionsGBOptimum start control (OSC)Your thermostat includes an optional optimum start control. This feature allows you to set the time at

Strona 19

26User InstructionsGBOption 1 - Enable or disable A/B programming (option 41 set to 5+2)This enables or disables the A/B programming option. Press +

Strona 20

27Option 10 - Frost/ thermostat mode settingThis feature allows the default frost/thermostat mode temperature to be set. Press + until Option 10 is di

Strona 21

28User InstructionsGBOption 13 - Optimum start control/Delayed start event setting(Option 11 set to 1 or 2)The Optimum start or delayed start control

Strona 22 - User Overrides

29Overview of installer selectable features which may a ect the operation of your thermostatTemperature range limitationThis allows the installer to

Strona 23

3Installation InstructionsProduct Speci cationPlease Note:This product should only be installed by a quali ed electrician or competent heating insta

Strona 24 - Delay start feature

30User InstructionsGBResetting the unitPartial reset: Press RESET (used to restart micro-computer) if display freezes for any reason. This does not re

Strona 25 - Programming Options

31Settings ReferenceNote to installers: Please use this table to record changes to default settings.Installer SettingsOption Description Installer Se

Strona 26

32Danfoss Randall LtdAmpthill RoadBedfordMK42 9ERTel: 01234 364621Fax: 01234 219705Part No. 40798v02s3-00 02/08Still having problems?Call your local

Strona 27

4Installation InstructionsGBInstallation First, remove the wallplate from the back of the unit. From the top left hand corner of the wallplate, th

Strona 28

5Installation InstructionsGB123Cable AccessWiringLNDEBCADE24VOutput Connections, all hard wired modelsPower Supply ConnectionsM 230V ModelsM 24V Model

Strona 29 - Keyboard lock

6Models with remote sensor inputsTerminal block for remote control/sensing is located on the circuit board above the battery compartment.Installation

Strona 30 - Service Interval Timer

7RX1RX2 & RX31234ELECTRONICSNLCOMZONE1 ONZONE1 OFFAELECTRONICSBC123456NLZONE1 ONZONE1 OFFZONE2 ONZONE3 ONCOMTERMINAL 6 RX3 ONLYRX Receiver Wiring

Strona 31 - Settings Reference

8Installer advanced programming optionsTP5000 Si incorporates an additional number of advanced features which can be set by the installer to improve t

Strona 32 - Department on 0845 121 7400

9Service Interval TimerInstructions on how to access this feature are available from our customer support desk. Please note these are only issued to b

Komentarze do niniejszej Instrukcji

Brak uwag