MODEL
HOTJET 8i
HOTJET 11i
HOTJET 15i
Electrical connection
1/N/PE ~230 V, 50 Hz
1/N/PE ~230 V, 50 Hz
1/N/PE ~230 V, 50 Hz
Power supply - 1 phase
230V / 1 / 50 Hz
230V / 1 / 50 Hz
230V / 1 / 50 Hz
Compressor
Copeland scroll
Copeland scroll
Copeland scroll
Service current [A]
15 A
15A
914 A
Starting current [A]
61 A
84 A
84A
Maximum service current [A]
20 A
20 A
20 A
Compressor protection [A]
25 B
32 B
32B
Compressor supply line (n x
mm2)
3x4
3x4
3x4
Noise level
Sound power Lw [dB(A)]
< 50
< 50
< 50
Sound pressure Lp [dB(A)]
< 37
< 37
< 37
Equipment
Control electronics Siemens
RVS41
yes (optionally RVS61)
yes (optionally RVS61)
yes (optionally RVS61)
Operator panel AVS37 on the
device
yes
yes
yes
Wireless device QAA78
optional
optional
optional
External switchboard with
electronics
optional (the whole wiring system is housed in external switchboard)
optional (the whole wiring system is housed in external switchboard)
optional (the whole wiring system is housed in external switchboard)
Soft start unit
optionally Danfoss
optionally Danfoss
optionally Danfoss
Condensate pump
optional
optional
optional
Integration into cascade
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Bivalence (back-up power
supply)
External tubular electric boiler
optionally (three-stage 2.5 5 7.5kW)
optionally (three-stage 2.5 5 7.5kW)
optionally (three-stage 2.5 5 7.5kW)
Electric cartridges in storage
reservoir
supported
supported
supported
External gas or electric boiler
supported
supported
supported
Electric post heating of boiler
supported
supported
supported
Solid fuel boiler
supported discharge of storage reservoir if it is overheated
supported discharge of storage reservoir if it is overheated
supported discharge of storage reservoir if it is overheated
*) Values as A2/W35 mean: intake air temperature is 2 ° C,
outlet water temperature from the heat pump is 35 ° C. Values are reported according to
standards EN 14511-1 to 4:2005
"" """"
Hotjet CZ s.r.o.! ! 22 z 46
Operating instructions and installation of heat pumps Hotjet (3.08/2010/01)
!!