3.2. Technical data of heat pump Hotjet “ ask “
The latest range of the air-to-water compact design heat
pumps for external installation feature advanced design
and high heating factor at affordable price.
Basic information
Compact dimensions
Air is the source of heat
Intended for attendance-free water heating up to
55°C.
Suitable for floor and radiator heating systems
Compressor cooling support
Hot water for space heating and service hot water
supply central control by means of supplied
regulation system
Choice from two regulators and an option for further
extension
Wired or wireless control
Stainless steel, unpainted finish
Wide range of accessories
Advantages
Ideal for new objects without internal spaces.
State-of-the-art technology with a front-end
electronics for affordable price.
Installation position
Intended for outdoor installation next to a building
structure or on its roof
Characteristics
Heat source: air
Noise suppression:
Use of scroll compressor design eliminates
traditional pistons and valves
Compressor and cooling circuit multiple spring
suspension
Solid and compact foundation slab
Multiple layer noise-proof insulation on covers
Low speed, 630mm large diameter serrated blades
fan
Control units:
AVS37 (standard) control panel in switchboard
without space temperature sensing (resolved with
the use of an external thermostat)
QAA78 wireless unit (optional) combined space and
service device
QAA78 advantages:
the heat pump and the hot water for space heating
and service hot water supply can be controlled from
anywhere in the house/building
space thermostat function, informs the regulator of
the local unit’s temperature status
Heating system connection support /
alternatives:
direct connection to the heating system without
using a storage reservoir
Two or four-point connection to the storage reservoir
Storage reservoir support by means of a floating
boiler
Storage reservoir (accumulation tank):
not required (subject to evaluation)
equithermal charging availability
availability of so-called forced charging, when the
required temperature is reached through charging.
The function’s initiation can be linked to time or
command controlled switching between electricity
tariffs. The advantage is the possibility of heat
“collection” during favourable weather conditions,
e.g. during higher air temperatures.
Bivalent source:
electrical cartridges support in the flow or in the
reservoir
External sources support (existing gas, electricity
and other energy driven boilers)
Three or single-stage bivalent controlز
Hotjet CZ s.r.o.! ! 25 z 46
Operating instructions and installation of heat pumps Hotjet (3.08/2010/01)
!!