MODEL
8s
11s
15s
18s
22S
35S
50S
Starting current [A]
Compressor
protection [A]
Compressor supply
line (n x mm2)
Noise level
Sound power Lw [dB
(A)]
Sound pressure Lp
[dB(A)]
Equipment
Control electronics
Siemens RVS41
Operator panel AVS37
on the device
Wireless device
QAA78
External switchboard
with electronics
Soft start unit
Condensate pump
Integration into
cascade
Bivalence (back-up
power supply)
External tubular
electric boiler
Electric cartridges in
storage reservoir
External gas or
electric boiler
Electric post heating
of boiler
Solid fuel boiler
18
20
23
36
36.4
55
80
16B
16B
16B
20B
20B
32A char B
40A char C
5x1,5
5x1,5
5x1,5
5x1,5
5x2,5
5x4
5x10
< 50
< 50
< 50
< 50
< 50
< 60
< 60
< 40
< 40
< 40
< 40
< 40
< 50
< 50
yes, (optionally RVS61)
yes, (optionally RVS61)
yes, (optionally RVS61)
yes, (optionally RVS61)
yes, (optionally RVS61)
yes, (optionally RVS61)
yes, (optionally RVS61)
yes,
yes,
yes,
yes,
yes,
yes,
yes,
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
optionally Danfoss
optionally Danfoss
optionally Danfoss
optionally Danfoss
optionally Danfoss
optionally Danfoss
optionally Danfoss
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Optionally (three-stage 2.5 5 7.5kW)
Optionally (three-stage 2.5 5 7.5kW)
Optionally (three-stage 2.5 5 7.5kW)
Optionally (three-stage 2.5 5 7.5kW)
Optionally (three-stage 2.5 5 7.5kW)
Optionally (three-stage 2.5 5 7.5kW)
Optionally (three-stage 2.5 5 7.5kW)
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported discharge of storage reservoir if it is overheated
Supported discharge of storage reservoir if it is overheated
Supported discharge of storage reservoir if it is overheated
Supported discharge of storage reservoir if it is overheated
Supported discharge of storage reservoir if it is overheated
Supported discharge of storage reservoir if it is overheated
Supported discharge of storage reservoir if it is overheated
Hotjet CZ s.r.o.! ! 34 z 46