3.4. Technical data of heat pump Hotjet “ w “
New models of heat pumps ground – water and water –
water bring along completely new construction of the
box, cooling circuit and control electronics. In a simplified
way we can say that there is nothing left from the original
model.
Basic information
• Compact size with a possibility of installation towards
the wall.
• Source of heat is a ground collector, borehole or well.
• It is designed for unmanned water heating up to 55°C.
• It is suitable for floor and radiator systems
• Regulation maintains heating of domestic hot water
(DHW)
• Compact construction does not require much space
(it takes up 0.35m2)
• Support of passive or compressor cooling
• Central control of heating and DHW heating through
supplied regulation
• Choice out of 2 regulators with a possiblility of further
extension
• Wired and wireless control
• Effecitve anti-corrosion protection
• Wide range of accessories
Advantages
• In comparison to air – water system:
• More stable power output
• Higher heating factor
• No aerodynamic noise
• It is not influenced by weather conditions
• High technology with top electronics at reasonable
price.
Installation position
Source of heat: ground collector, borehole, well, service
water
Place of installation: anywhere inside a building – utility
room, cellar, garage…
External part of installation: primary source – borehole,
ground collector, wells
Characteristics
Noise suppression:
•
Compressor scroll without mechanically movable
pistons and valves
•
Multiple spring-loaded housing of compressor and
cooling circuit
•
Solid compact baseplate
•
Multiply insulation against noise on the covers
Space required: the heat pump takes up the area of
0.35m2. Upper cover height is approximately 1m.
Passageway of 60cm is fully sufficient for the installation.
Control units:
AVS37 (standard)
•
Operator panel in a switchboard
•
Without spatial temperature reading (solved by
external thermostat)
QAA78 wireless unit (optional)
Combined spatial and operating device
Advantages of QAA78:
•
Heat pump, heating system and heating of DHW may
be controlled from any place in the house.
•
Spatial thermostat function informs the regulator of
temperature in the place where the unit is placed.
Support of connection to the heating system:
•
Connection without surge tank, directly to the heating
system
•
Connection with a surge tank point-to-point, four-point
•
Support for surge tanks with floating boiler
Surge tank (storage reservoir):
•
Is not necessary (requires consideration)
•
May be charged equithermally
•
May be charged, so-called, forcedly, when it is charged
up to the required temperature. Startup of this function
may be linked to switching electrical energy rates,
certain time or it can be controlled by external
command. One of the advantages is the possibility of
“collection” of heat when the conditions are better. For
example the air temperature is higher.
Hotjet CZ s.r.o.! ! 39 z 46
Operating instructions and installation of heat pumps Hotjet (3.08/2010/01)
!!