66 User Guide DLX Series L00410623-1
6.2.8.1. Inverter
Inverter displays a summary of the most important statistics of the inverter from today, the
last month, the last year and in total since Start Up.
Energy
Inverter’s total energy production [kWh]
Earnings
Cash value of the feed-in energy in currency/kWh
CO
2
avoided
Avoided CO
2
emissions [kg/kWh] compared to fossil fuel
Peak Power
Inverter’s largest instantaneous amount of power production [W]
6.2.8.2. Plant
Plant displays a summary of the most important statistics of the PV plant from today, the
last month, the last year and in total since Start Up.
Energy
Plant’s total energy production [kWh]
Earnings
Cash value of the feed-in energy in currency/kWh.
CO
2
avoided
Avoided CO
2
emissions [kg/kWh] compared to fossil fuel
Peak Power
Plant’s largest instantaneous amount of power production [W]
6.3. Connection between Inverter and Computer
The site performance can be checked remotely by using a computer. The connection can
be achieved between the inverter and the computer either directly or via a network.
6.3.1. Without a Network
To connect the inverter and the computer directly a regular Ethernet cable is needed. If the
network card in the computer does not support Autosense, a crossover cable is needed to
create a connection to the inverter.
Figure 6.3.1:Connection without network
1. Follower inverter
2. Master inverter
3. CAN bus cable
4. Ethernet cable
5. RS-485 cable
6. Computer
7. Data logger
NOTICE
With several inverters connected together via CAN bus the Ethernet cable must be
attached to the master inverter only.