5.1.9 8-** Comm. and Options
Par.
No. #
Parameter description Default value 2-set-up Change
during
operation
Conver-
sion index
Type
8-0* General Settings
8-01 Control Site [0] Digital and ctrl.word All set-ups TRUE - Uint8
8-02 Control Source [1] FC Port All set-ups TRUE - Uint8
8-03 Control Timeout Time 1.0 s 1 set-up TRUE -1 uint_16
8-04 Control Timeout Function [0] Off 1 set-up TRUE - Uint8
8-3* FC Port Settings
8-30 Protocol [0] FC 1 set-up TRUE - Uint8
8-31 Address 1.0 N/A 1 set-up TRUE 0 uint_8
8-32 Baud Rate ExpressionLimit 1 set-up TRUE - Uint8
8-33 Parity / Stop Bits ExpressionLimit 1 set-up TRUE - Uint8
8-35 Minimum Response Delay 0.01 s 1 set-up TRUE -3 uint_16
8-36 Maximum Response Delay ExpressionLimit 1 set-up TRUE -3 uint_16
8-37 Maximum Inter-char delay 0.025 s 1 set-up TRUE -3 uint_16
8-5* Digital/Bus
8-50 Coasting Select [3] Logic OR All set-ups TRUE - Uint8
8-51 Quick Stop Select [3] Logic OR All set-ups TRUE - Uint8
8-52 DC Brake Select [3] Logic OR All set-ups TRUE - Uint8
8-53 Start Select [3] Logic OR All set-ups TRUE - Uint8
8-54 Reversing Select [0] Digital input All set-ups TRUE - Uint8
8-55 Set-up Select [3] Logic OR All set-ups TRUE - Uint8
8-56 Preset Reference Select [3] Logic OR All set-ups TRUE - Uint8
8-7* BACnet
8-70 BACnet Device Instance 1 N/A 1 set-up TRUE 0 Uint32
8-72 MS/TP Max Masters 127.0 N/A 1 set-up TRUE 0 uint_8
8-73 MS/TP Max Info Frames 1.0 N/A 1 set-up TRUE 0 uint_16
8-74 "I am" Service [0] Send at power-up 1 set-up TRUE - Uint8
8-75 Intialisation Password [admin] 1 set-up TRUE 0
VisStr[2
1]
8-8* FC Port Diagnostics
8-80 Bus Message Count 0.0 N/A 1 set-up TRUE 0 uint_32
8-81 Bus Error Count 0.0 N/A 1 set-up TRUE 0 uint_32
8-82 Slave Messages Rcvd 0.0 N/A 1 set-up TRUE 0 uint_32
8-83 Slave Error Count 0.0 N/A 1 set-up TRUE 0 uint_32
8-84 Slave Messages Sent 0.0 N/A 1 set-up TRUE 0 uint_32
8-85 Slave Timeout Errors 0.0 N/A 1 set-up TRUE 0 uint_32
8-88 Reset FC port Diagnostics [0] Do not reset 1 set-up TRUE - Uint8
8-9* Bus Feedback
8-94 Bus Feedback 1 0.0 N/A All set-ups TRUE 0 Int16
Parameter Lists VLT HVAC Basic Drive Programming Guide