Other connections
Large display (Solar-Log500, Solar-Log1000)
136 of 268 Solar-Log
1000/500/200
Installation
6 Other connections
6.1 Large display (Solar-Log
500
, Solar-Log
1000
)
Large displays can be connected to the Solar-Log™ via two interfaces:
Connection through RS485 output
S0 pulse output
The connection through RS485 is preferable. Cable lengths can be up to
500 m and the data can be displayed selectively on the Solar-Log™.
Connection through RS485 A output
If inverters are connected and theses are using the RS422 interface (e.g. Fronius,
AEG, Riello), then it is not possible to connect a display through the bus.
If the display is looped through the same cable as the inverters, the display
must be configured accordingly in the interface parameters.
Wiring for displays made by Schneider-Displaytechnik
The wiring consists of a 3-pin control cable, (3 × 0.5 mm²) and terminal block
connector ( Page 15).
Terminal block connector (Solar-Log
1000
)
Further information about connection can be obtained from the manufacturer
of the display.
Wiring for displays from RiCo-Electronic
The wiring consists of a 2-pin control cable, (2 × 0.5 mm²) and terminal block
connector ( Page 15).
Terminal block connector (Solar-Log
1000
)
Further information about connection can be obtained from the manufacturer
of the display.