Faults
Fault messages
Solar-Log
1000/500/200
Installation 253 of 268
11.2 Fault messages
Status codes for export test transmission
Err no.
Message
Meaning
Remedy
Error when setting up the test connection or logging onto the server
101
DNS error
Type of Internet access
set to None.
A DNS server must be
entered.
There is no connection
to the network.
Set correct access type.
Enter correct DNS.
Check cables and
plugs.
102
Cannot open
socket.
Internal error
Prepare configuration
and data back up and
contact Support.
103
Cannot connect
socket
The connection is dis-
rupted by a firewall.
The server is overload-
ed.
Set appropriate ap-
provals in the firewall.
Try again later.
104
No answer from
the server.
There is a fault on the
FTP server.
Try again later.
Restart the FTP server.
105
Wrong response
from the server.
The FTP server used is
not supported or is not
configured correctly.
Use another FTP server
or check the configura-
tion.
106
User/password
incorrect.
The user name of pass-
word to access the FTP
was entered incorrectly.
Check spelling.
107
Wrong directory.
An incorrect directory
was set for the
transmission.
Check spelling.
Error when transferring the back up.
108
Unable to send the
file
Error when transferring data without losing the test connection.
111
Error in remote file
name
This is an internal error.
Contact support.
112
Error when setting
the representation
type.
The FTP server used is
not supported or not
configured properly.
Use another FTP server
or check the configura-
tion.