Danfoss TripleLynx CN Instrukcja Instalacji Strona 78

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 268
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 77
Connecting the inverters
Ever-Solar (Eversol TL RS485)
78 of 268 Solar-Log
1000/500/200
Installation
Procedure
CAUTION
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to
the RJ45 socket on the inverter.
Only connect inverters via the RS485/422 B Solar-Log interface.

Note concerning Solar-Log
1000
:
Only connect inverter using the RS485/422 B interface.
1 If you are fabricating the cable yourself, connect the wires as shown in the
following diagram:
Solar-Log™ terminal block connector
RJ45 inverter
Terminal
Pin
1
PIN 3
4
PIN 6
5
PIN 1
6
PIN 2
2 Insert the RJ45 plug into any RJ45 socket on inverter 1.
3 If only one inverter is to be connected terminate this in accordance with the
inverter instructions.
4 Insert the terminal block connector in the RS485/422 B socket on the So-
lar-Log™.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a network cable (patch cable)
Where to connect: RJ45 socket on the outside of the inverter
Procedure
1 Insert the RJ45 plug into any RJ45 socket on inverter 1.
2 Insert the other end of the wire into any RJ45 socket on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter in accordance with the inverter instructions.
Przeglądanie stron 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 267 268

Komentarze do niniejszej Instrukcji

Brak uwag