Solar-Log1000: Configuration at the unit
RS485 wireless communications package: Testing connection (Advanced/RS485-wireless- package)
244 of 268 Solar-Log
1000/500/200
Installation
10.16 RS485 wireless communications package: Testing connection
(Advanced/RS485-wireless- package)
This dialogue box is used to test the wireless connection to the optional
RS485 wireless communications package.
Note
The test function is only available with Solar-Log
1000
.
Before the connection test, the RS485 interface to be tested must already be
configured in the Config./Start/Initial configuration dialogue box and the
wireless modules must be already set to the signalling speed of the inverters.
A red test adapter (loopback) is available for testing the wireless connection.
Note
For detailed instructions on how to install and set up the RS485 wireless
communications package, see the manual that accompanies the package.
To test the RS485 wireless connection:
Select Config./Advanced/RS485 wireless package from the menu.
A dialogue box opens for testing the RS485 wireless package.
Dialogue boxes
RS485-A
Display field which indicates the inverter to which the wireless package on
the RS485 A interface is assigned, or whether the connection is still free
RS485-B
Display field which indicates the inverter to which the wireless package on
the RS485/422 B interface is assigned, or whether the connection is still free
Test
This button to used to start the transmission test.