Configuration at a PC
Solar-Log1000 Defining system groups (Basic/System Groups)
Solar-Log
1000/500/200
Installation 157 of 268
Groups section
1 Tick The inverters are divided into groups.
The group definition window appears.
Group definition section
Up to 10 system groups can be defined, each containing up to 15 inverters:
2 Click on Add
A list of inverters is displayed:
3 Click on the desired inverter in the list
The inverter is transferred into the group definition box.
You can click on Delete to remove individual inverters from the group definition.
4 For each inverter, assign a unique name under Label for each system group
5 For each inverter, enter the individual amount under Feed-in tariff (Cents)
6 For each inverter, enter the target yield quantity under Yearly quota
(kWh/kWp)
7 When you click on Save, the settings become active immediately.